Shandong Jingheng Yuxin medical equipment Co., Ltd.
E N中文

Product Center

MST-N series cabinet pressure steam sterilizer

MST-N series cabinet pressure steam sterilizer uses saturated steam as sterilization medium, through the way of gravity exhaust steam to exclude cold air, so that the saturated steam can completely penetrate to the surface of the article, using high temperature saturated steam under high pressure to kill all microorganisms and their spores, the sterilization effect is reliable, is the most effective physical sterilization method.It is widely used in pharmaceutical, biological engineering, laboratory and other fields to sterilize fabrics, instruments, rubber, liquid

Main performance and features:
◆ Using microcomputer control technology, touch screen operation, the whole process (heating, sterilization, exhaust steam, drying) the whole process of automatic program operation.
Touch screen automatically displays operating status, temperature, pressure, time and other parameters as well as fault alarm information.
With fabric, instrument, rubber, liquid, custom 4 sterilization procedures for users to choose.
Built-in high efficiency steam generator, can quickly produce constant pressure steam, do not pollute sterilized goods.
Optional configuration of micro printer, real-time sterilization process and fault alarm information.
When the program cycle ends, there is a buzzer prompt when the fault alarm occurs.
 Safety device:
Overtemperature automatic protection device: the system automatically cuts off the power supply when the temperature exceeds the setting.


 Door safety interlocking device: electronic door lock is adopted. Only when the door is closed in place, the sterilizer can start the working procedure. If there is pressure in the inner room or the power supply is not connected, the electronic door lock locks the door handle and the door cannot be opened.

 Dry burning alarm device: when the water level is lower than the low water level, the heating power will be cut off automatically and alarm information will be displayed.

 Overpressure relief valve: when the set pressure is exceeded, the relief valve opens to release the pressure.

 Electronic circuit safety device: DC control circuit with overvoltage overload protection, ac main circuit with short circuit protection.


Technical parameters:
Design pressure: 0.3MPa;
Rated working pressure: 0.23MPa
Pressure display accuracy: 0.1kpa
Sterilization temperature: 105 ~ 136℃ 
Temperature display accuracy 0.1℃
Maximum temperature: 136℃ 
Temperature uniformity: ≤±0.5℃;
Cavity material: SUS304 stainless steel


mode

volume

Chamber size

Overall dimensions

 Weight

POWER

(L)

(Φ×L)

(L×W×H)

Kg

MST-45N

45

316×590

750×520×500

 55

220V 50Hz  3.0Kw

MST-60N

60

380×500

985×600×1450

105

380V 50Hz  4.5Kw

MST-80N

80

380×700

985×600×1450

120

380V 50Hz  5.7Kw

MST-135N

135

500×700

1000×710×1550

200

380V 50Hz  9.35Kw

MST-185N

185

500×950

1250×710×1550

230

380V 50Hz  10.8Kw

MST-300N

300

630×1000

1350×950×1750

350

380V 50Hz  12Kw